DUPONT E I DE NEMOURS & CO INC AUTOMOTIVE PRODS D -- 2319S LACQUER THINNERS & CLEANING SOLVENTS -- 8010-00F049331
===================== Product Identification =====================
Product ID:2319S LACQUER THINNERS & CLEANING SOLVENTS
MSDS Date:01/01/1995
FSC:8010
NIIN:00F049331
=== Responsible Party ===
Company Name:DUPONT E I DE NEMOURS & CO INC AUTOMOTIVE PRODS D
Address:BRANDYWINE BLDG 3332 1007 MARKET ST
City:WILMINGTON
State:DE
ZIP:19898-5000
Country:US
Info Phone Num:800-441-7515/800-441-3637
Emergency Phone Num:800-441-3637/800-441-7515
Preparer's Name:T R LOUER
CAGE:23027
=== Contractor Identification ===
Company Name:DU PONT E I DE NEMOURS & CO FABRICATED PROD DEPT
Address:1007 MARKET ST BRANDYWINE BLDG 3332
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-3637
CAGE:90227
Company Name:TETRA MFG CORP (CAGE CANCELLED)
Address:CAGE CANCELLED
City:WESTBURY
State:NY
ZIP:11590
Country:US
Phone:NONE
CAGE:23027
============= Composition/Information on Ingredients =============
Ingred Name:ACETIC ACID (GLACIAL), ETHANOIC ACID *96-2*
CAS:64-19-7
RTECS #:AF1225000
OSHA PEL:25 MG/CUM
ACGIH TLV:25 MG/CUM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL
CARBINOL (IARC CANCER REVIEW GROUP 3) *96-2*
CAS:67-63-0
RTECS #:NT8050000
Other REC Limits:400 PPM
OSHA PEL:400 PPM
ACGIH TLV:400 PPM
Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY CAUSE GASTROINTESTINAL
DISTRESS. INHALATION: NOSE & THROAT IRRITANT. OVEREXPOSURE TO
SOLVENTS MAY LEAD TO PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. EYES:
MAY CAUSE IRRITATION/BURNING. SK IN: IRRITATION W/DISCOMFORT,
DERMATITIS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:GI DISTRESS, IRRITATION, EYE WATERING,
HEADACHES, NAUSEA, DIZZINESS, LOSS OF COORDINATION, BURNING
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. EYES: IMMEDIATELY FLUSH
W/PLENTY OF WATER FOR 15 MINS. SKIN: WASH W/SOAP & WATER. OBTAIN
MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:<73F
Lower Limits:0.8
Upper Limits:36.5
Extinguishing Media:WATER SPRAY, FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:WEAR FULL PROTECTIVE EQUIPMENT W/SELF
CONTAINED BREATHING APPARATUS. WATER FROM FOG NOZZLES MAY BE USED
TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILDUP.
Unusual Fire/Explosion Hazard:WHEN HEATED >FLASH POINT, EMITS FLAMMABLE
VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLOSIVE. FINE
MISTS/SPRAYS MAY BE FLAMMABLE AT TEMPS 120F. CLOSE CONTAINER
AFTER EACH USE. GROUND CONTAINERS WHEN POURING. OBSERVE LABEL
PRECAUTIONS. KEEP AWAY FROM HEAT, SPARKS & FLAME.
Other Precautions:DON'T SAND FLAME CUT, BRAZE/WELD DRY COATING W/O A
NIOSH/MSHA APPROVED RESPIRATOR/APPROPRIATE VENTILATION. DON'T
PERMIT ANYONE W/O PROTECTION IN THE PAINTING AREA. PREVENT SKIN
CONTACT & DON'T BREATHE VAPORS/MISTS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR A PROPERLY FITTED VAPOR/PARTICULATE
RESPIRATOR APPROVED BY NIOSH/MSHA (TC-23C) FOR USE W/PAINTS DURING
APPLICATION & UNTIL ALL VAPORS & SPRAY MISTS ARE EXHAUSTED. IN
CONFINED SPACES, WEAR A POSIT VE PRESSURE, SUPPLIED AIR RESPIRATOR.
Ventilation:SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS 1
VOC Grams/Liter:6.6
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Percent Volatiles by Volume:93-100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:HEAT, SPARKS, FLAME, STORAGE >120F & OTHER
IGNITION SOURCES
Hazardous Decomposition Products:CO, CO2, SMOKE
==================== Disposal Considerations ====================
Waste Disposal Methods:DON'T ALLOW MATERIAL TO CONTAMINATE GROUND WATER
SYSTEMS. INCINERATE ABSORBED MATERIAL IAW/LOCAL, STATE & FEDERAL
REGULATIONS. DON'T INCINERATE IN CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.