SHERWIN WILLIAMS CO -- FLUORESCENT SPRAY, FS920 YELLOW -- 8010-00N076262
=====================  Product Identification  =====================

Product ID:FLUORESCENT SPRAY, FS920 YELLOW
MSDS Date:04/15/1996
FSC:8010
NIIN:00N076262
=== Responsible Party ===
Company Name:SHERWIN WILLIAMS CO
Address:31600 SOLON RD
City:SOLON
State:OH
ZIP:44139
Country:US
Info Phone Num:800-247-3270
Emergency Phone Num:216-566-2917
CAGE:54626
=== Contractor Identification ===
Company Name:SHERWIN WILLIAMS COMPANY
Address:101 PROSPECT AVE NW
City:CLEVELAND
State:OH
ZIP:44115
Country:US
Phone:216-566-2902
CAGE:54626
Company Name:SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
Address:26300 FARGO AVENUE
Box:City:BEDFORD HEIGHTS
State:OH
ZIP:44146
Country:US
Phone:216-292-7400 OR 216-595-8634
CAGE:09800

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE. VP:760.
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 15%
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT

Ingred Name:BUTANE. VP:760.
CAS:106-97-8
RTECS #:EJ4200000
Fraction by Wt: 14%
OSHA PEL:800 PPM
ACGIH TLV:800 PPM

Ingred Name:LACOLENE; (LT ALIPHATIC HYDROCARBON). VP:59.
CAS:64742-89-8
Fraction by Wt: 4%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (MINERAL
    SPIRITS). VP:2.
CAS:64742-88-7
Fraction by Wt: 7%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:TOLUENE (SARA 313) (CERCLA). VP:22.
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 44%
OSHA PEL:200 PPM
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SUPP DATA:HAZARD. SYMPTOMS MAY NOT BE IMMEDIATELY APPARENT.
    OBTAIN MEDICAL ATTENTION.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP:INTENTIONAL MISUSE BY DELIB CONCENTRATING &
    INHALING CONTENTS CAN BE HARMFUL/FATAL. THIS PROD (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:CONTAINS CHEM KNOWN TO STATE OF CALIFORNIA TO CAUSE
    CANCER, BIRTH DEFECTS & OTHER REPRO HARM. NOTE:TOLUENE(ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:APPEARS ON NAVY LIST OF OCCUP CHEM REPRO HAZS. SEEK
    CONSULTATION FROM APPROP HLTH PROFESSIONALS CONCERNING(ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:LATEST HAZARD LIST INFO & SAFE HANDLING & EXPOSURE
    INFO .
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:PROCS. CONTENTS UNDER PRESS. DO NOT PUNCTURE,
    INCIN/EXPOSE TO TEMP >120F. HEAT FROM SUNLIGHT, (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:RADIATORS, STOVES, HOT WATER & OTHER HEAT SOURCES
    COULD CAUSE CNTNR TO BURST. DO NOT TAKE INTERNALLY. (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:KEEP OUT OF REACH OF CHILDREN. USE ONLY W/ADEQ VENT.
    AVOID BRTHG VAP & SPRAY MIST. AVOID CONT W/SKIN & (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:EYES. THESE COATINGS MAY CONTAIN INGS CLASSIFIED AS
    NUISANCE PARTICULATES WHICH MAY BE PRESENT AT HAZ (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:LEVELS ONLY DURING SANDING/ABRADING OF DRIED FILM.
    IF NOT SPECIFIC DUSTS ARE LISTED, APPLIC LIMS FOR (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:NUISANCE DUSTS ARE ACGIH TLV 10 MG/M3 (TDUST), OSHA
    PEL 15 MG/M3 (TDUST), 5 MG/M3 (RESPIRABLE FRACTION).
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
    CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
    PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE:IRRIT OF EYES, SKIN &
    RESP SYS. MAY CAUSE NERV SYS DEP RESS. EXTREME OVEREXP MAY RSLT IN
    UNCON& POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OF EXCESSIVE EXPOS TO VAPS/SPRAY MIST.
    REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE SKIN
    EXPOS. CHRONIC:PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE EFTS TO
    LIVER, URINARY, BLO OD-FORMING, CVS & REPRO SYS. RPTS HAVE ASSOC
    RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG. (ING 8)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
    QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
    CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LARGE
    AMOUNTS OF	WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
    INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. GIVE
    SEVERAL GLASSES OF WATER. SEEK MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:1%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
    WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
    WATER MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:EXTREMELY FLAMM. CLSD CNTNRS MAY EXPLODE
    (DUE TO BUILD-UP OF PRESS) WHEN EXPOS TO EXTREME HEAT. ISOLATE FROM
    HEAT, ELEC EQUIP, SPKS & OPEN FLAME. (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
    REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DOL STOR CATEGORY-1A. CONTENTS ARE
    EXTREMELY FLAMM. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME. VAPS WILL
    ACCUM READILY & MAY IGNITE EXPLOSIVELY.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA
    VENTED; DO NOT SMOKE; EXTING ALL FLAMES, PILOT LIGHTS & HEATERS;
    TURN OFF STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF
    IGNIT. CONSULT NFPA CODE . USE APPRVD BONDING & GROUNDING(ING 12)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
    APPLIC LIMS BY VENT, WEAR A PROPERLY FITTED NIOSH APPRVD ORG
    VAP/PARTICULATE RESP FOR PROT AGAINST INGS. WHEN SANDING/ABRADING
    DRIED FILM, WEAR A NIOSH APP RVD DUST/MIST RESP FOR DUST (SUPP
    DATA)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPT IF EXPOS TO INGS IS
    MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS
    TO EXTREME HEAT. RESP PROT:WHICH MAY BE GENERATED FROM THIS PROD,
    UNDERLYING PAINT/ABRASIVE. VENT:1910.90, 1910.107, 1910.108. EXP LO
    HAZ:APPLICATION TO HOT SURFS REQS SPECIAL PRECS. DURING EMER CNDTNS
    OVEREXP TO DECOMP PRODS MAY CAUSE HLTH (ING 7)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:<690F,<366C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.75 
VOC Grams/Liter:5.28
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:>75

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
    MONOXIDE, HYDROGEN CHLORIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
    RCRA (40 CFR 261). WASTE MUST BE TESTED FOR IGNITABILITY TO
    DETERMINE APPLIC EPA HAZ WASTE NUMBERS. DO NOT INCIN. DEPRESSURIZE
    CNTNR. DISP OF I/A/W FED ERAL, STATE & LOCAL REGS REGARDING
    POLLUTION.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.